fbpx

MC Wall

  • a system used to design modern curtain walls; the system is a basis for facade structures: MC Passive+, MC Glass and MC Fire, MC Glass Fire (a solution for fire protection); the MC Wall system offers many possibilities
  • of creating the installation; the system offers structures to be opened on the facade: parallel windows (MC PW) and roof windows (MC RW)
  • mullion-transom visual width: 55 mm
  • the curtain wall in the MC Wall system consists of mullions and transoms fastened by stainless steel bolts; there are 2 x ø 6 stainless steel fasteners per joint; the fasteners ensure very high load capacity of the mullion-transom connection, both in the wind pressure plane and the infill load plane; the solution does not prevent using traditional transom brackets or fastening transoms only with screws attached from the face side
  • a wide range of mullions and transoms suitable for static requirements
  • the insulators can be built accordingly to the infill thickness
  • application of vapour-proof and breather membranes on the perimeter of the facade is easier, in accordance with new guidelines for installation of aluminium structures
  • a wide range of decorative cover caps makes it possible to obtain varied visual effects on the curtain wall
  • the option of bending profiles (detailed specification of profiles and detailed technical parameters of profile bending process are available in the customer area of the website www.aliplast.pl)
  • a wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour
TECHNICAL SPECIFICATION
SYSTEM MATERIAL DEPTH OF FRAME DEPTH OF LEAF GLAZING RANGE ACOUSTIC TYPE OF WINDOWS TYPE OF DOORS
MC WALL aluminium 10-326 mm 0-89 mm** 45 (-2,-5) dB from 10,2 - 4092 cm4* from 7,0 to 1831,1 cm4*
PERFORMANCE
SYSTEM THERMAL INSULATION UF* AIR PERMEABILITY WINDLOAD RESISTANCE WATERTIGHTNESS
MC WALL Uf from 0,84 W/m2K Class AE1500; EN 12152 2600Pa; EN 13116 Class RE1950; EN 12154

*Thermal insulation is dependent on a combination of profiles and thickness of the filling